A fix is available
APAR status
Closed as program error.
Error description
Event attached to a Calendar in Heritage coach is being called twice 1) Create a Human service 2) Drag and Drop Heritage coach 3) Drag and Drop date selector control 4) For control #3 , click on Events tab under properties 5) Create "onClick" event 6) Fill in <start> alert("I am an alert Box!"); </end> under script 7) Run service 8) As soon as you click on date selector , you will find alert box popping up twice
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: Users of BPM Express, BPM Standard, and * * BPM Advanced. * **************************************************************** * PROBLEM DESCRIPTION: An Event attached to Date Selector * * Control in Heritage coachs gets called * * twice. * **************************************************************** * RECOMMENDATION: * **************************************************************** pageLoadOperation() gets called twice, once when coach page loads and second if it is called in setupInitialVisibility(), so same method gets called twice when page loads. Onclick event is wrapped in an anonymous function, anonymous function is bound to Date selector when pageLoadOperations() gets called. pageLoadOperations() is called twice when page loads, therefore the anonymous function gets bound to Date Selector twice, so when you click it, event executes twice.
Problem conclusion
To correct this functionality, pageLoadOperations() function had to be removed from coach_designer.js to prevent duplicate execution of event. Fix is available on FixCentral. Install/Dependency information is available in the readme.txt on FixCentral. When the user goes to the download files page in FixCentral, the readme will be available with the fix package as a separate download.
Temporary fix
Comments
APAR Information
APAR number
JR43760
Reported component name
BPM STANDARD
Reported component ID
5725C9500
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-08-14
Closed date
2012-09-26
Last modified date
2012-09-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BPM STANDARD
Fixed component ID
5725C9500
Applicable component levels
R800 PSY
UP