A fix is available
APAR status
Closed as program error.
Error description
An error "(40802) The Source Stage does not contain information for this link" is reported when trying to rename a job design link name. This problem can occur because the transformer stage has a derivation expression which is longer than 32767 characters.
Local fix
- open designer to edit job design - select transformer stage end of link that cannot be renamed and drag to space on the canvas - rename dangling link - select dangling end and drag back to transformer stage
Problem summary
When renaming a transformer stage input link we attempt to update refernces to input link columns in derivation expressions. If any derivation expression nis longer that 32767 this fails with an arithmetic overflow.
Problem conclusion
Issue has been fixed in source and fix will be included in future releases.
Temporary fix
Comments
APAR Information
APAR number
JR42030
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
810
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-02-23
Closed date
2012-04-30
Last modified date
2012-04-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R850 PSN
UP