A fix is available
APAR status
Closed as program error.
Error description
If you have created a Descision Service containing a BAL Rule, which checks some status string and returns boolean value you may get the following error at runtime: ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ CWLLG0594E: An exception occurred while initializing the runnable thread. Error: com.lombardisoftware.component.common.workflow.WorkflowProcessIt emException: An error occurred in WhenToUpdateCRM_DS service, at step When to Update CRM DT. Detail message: GBRKL0012E : When parameterUsageAnalysis is set buildRuleset must be called before accessing parameters. com.lombardisoftware.component.common.workflow.WorkflowProcessIt emException: An error occurred in WhenToUpdateCRM_DS service, at step When to Update CRM DT. Detail message: GBRKL0012E : When parameterUsageAnalysisis set buildRuleset must be called before accessing parameters. at com.lombardisoftware.component.common.workflow.ExecutionJob.doJo b(ExecutionJob.java:415) at com.lombardisoftware.server.ejb.workflow.EJBWorkflowManagerBean. doResume WorkflowEngine(EJBWorkflowManagerBean.java:999) at com.lombardisoftware.server.ejb.workflow.EJBWorkflowManagerBean. resumeProcess(EJBWorkflowManagerBean.java:354) ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Local fix
The only way to get rid of this error is stopping the server, deleting tranlogs and temp files, and starting it again.
Problem summary
GBRKL0012E : WHEN PARAMETERUSAGEANALYSIS IS SET BUILDRULESET MUST BE CALLED BEFORE ACCESSING PARAMETERS.
Problem conclusion
iFix made available
Temporary fix
Comments
APAR Information
APAR number
JR41282
Reported component name
BPM STANDARD
Reported component ID
5725C9500
Reported release
750
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-11-23
Closed date
2012-01-20
Last modified date
2012-01-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BPM STANDARD
Fixed component ID
5725C9500
Applicable component levels
R750 PSY
UP
R751 PSY
UP