Fixes are available
DB2 Version 9.1 Fix Pack 7 for Linux, UNIX and Windows
DB2 Version 9.1 Fix Pack 5 for Linux, UNIX and Windows
DB2 Version 9.1 Fix Pack 6 for Linux, UNIX and Windows
DB2 Version 9.1 Fix Pack 6a for Linux, UNIX and Windows
DB2 Version 9.1 Fix Pack 7a for Linux, UNIX and Windows
DB2 Version 9.1 Fix Pack 8 for Linux, UNIX and Windows
DB2 Version 9.1 Fix Pack 9 for Linux, UNIX and Windows
DB2 Version 9.1 Fix Pack 10 for Linux, UNIX and Windows
DB2 Version 9.1 Fix Pack 11 for Linux, UNIX and Windows
DB2 Version 9.1 Fix Pack 12 for Linux, UNIX and Windows
APAR status
Closed as program error.
Error description
The .NET utility testconn20.exe will fail with an SQL1159 rc=7 e rror when issued on a 64-bit Windows platform using a 32-bit DB2 installation. . By default testconn20.exe is built using the /platform:anycpu op tion which means that it will use the 64-bit CLR on a 64-bit pla tform. This fails because the .NET data provider is 32-bit and uses the 32-bit Windows registry. This APAR will ensure that t estconn20.exe is built using /platform:x86 for 32-bit installati ons of DB2.
Local fix
Problem summary
Users Affected: DB2.NET application developers. Problem Description: SQL1159 rc=7 with testconn20.exe on 64-bit platform with 32-bit DB2.NET driver.
Problem conclusion
First fixed in DB2 UDB Version 9, Fixpak 5
Temporary fix
Comments
APAR Information
APAR number
JR28621
Reported component name
DB2 CUE WINDOWS
Reported component ID
5724B6201
Reported release
910
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-03-03
Closed date
2008-07-02
Last modified date
2008-07-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DB2 CUE WINDOWS
Fixed component ID
5724B6201
Applicable component levels
R910 PSN
UP
Document Information
Modified date: