IBM Support

JR61637: CDC STILL TAKES VALUES IN BYTES AFTER CHANGING SYSTEM PARAMETER USEREXIT_MAX_LOB_SIZE_KB UNLESS THE INSTANCE IS RESTARTED

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • CDC is taking value in bytes on changing value of system
    parameter userexit_max_lob_size_kb and only after instance
    restart it is taking that value in KB.
    

Local fix

  • Please restart CDC instance after setting this parameter.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * This issue affects clients using CDC 11.4.0.2-5507 and       *
    * older.                                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * CDC uses the wrong units to truncate LOBs in user exits.     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to IDR 11.4.0.2-5507 or newer.                       *
    ****************************************************************
    

Problem conclusion

  • Upgrading to IDR 11.4.0.2-5507 or newer resolves the issue.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR61637

  • Reported component name

    IS CDC ORACLE

  • Reported component ID

    5725E30OR

  • Reported release

    B40

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-10-24

  • Closed date

    2020-03-04

  • Last modified date

    2020-03-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    IS CDC ORACLE

  • Fixed component ID

    5725E30OR

Applicable component levels

  • RB40 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTRGZ","label":"InfoSphere Data Replication"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.4","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
25 August 2020