Direct links to fixes
APAR status
Closed as program error.
Error description
BPEL microflows are processed without database records. However, the indexer state observer produces database records for the events. As a result, BPEL microflow performance is reduced and the IBM Process Federation Server indexer throw exceptions because it finds process instance IDs in the database that do not have details.
Local fix
Problem summary
No additional information is available.
Problem conclusion
A fix is available for IBM BPM V8.5.7 cumulative fix 2017.03 that writes the indexer events for long-running processes only, and ignores events for microflows. To determine whether the cumulative fix is available, complete the following steps on Fix Central (http://www.ibm.com/support/fixcentral): 1. On the Select product tab, select WebSphere as the product group, IBM Business Process Manager with your edition from the WebSphere options, All as the installed version, and All as the platform, and then click Continue. 2. In the Text field, enter "cumulative fix", and click Continue. If cumulative fix 2017.03 is available, download and install it. When you download fix packages, ensure that you also download the readme file for each fix. Review each readme file for additional installation instructions and information about the fix. PRODUCT AFFECTED IBM Business Process Manager (BPM) Advanced
Temporary fix
Comments
APAR Information
APAR number
JR57095
Reported component name
BPM ADVANCED
Reported component ID
5725C9400
Reported release
857
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-12-01
Closed date
2017-01-12
Last modified date
2017-01-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BPM ADVANCED
Fixed component ID
5725C9400
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSFTN5","label":"IBM Business Process Manager Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"857","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information