Closed as program error.
Error description
Adding a row in a coach view renders a row that is not editable in any way. When you click +, you cannot actually add the value because the row is blank. This issue occurs only when you have a Date Time Picker coach view bound to a list of Date simple types (for example, dates.currentItem) and repeated within a Table. PRODUCTS AFFECTED: IBM Business Process Manager (BPM) Advanced IBM BPM Standard IBM BPM Express
Local fix
Create a business object, for example MyDateObject, and add the property of type Date to it. Bind the Table to the list of that type (for example, dates[]). Bind the Date Time Picker coach view to the property (for example, dates.currentItem.date).
Problem summary
When you have a Date Time Picker coach view bound to a list of Date simple types (for example, dates.currentItem) repeated within a Table stock control, the row becomes uneditable.
Problem conclusion
A fix will be included in IBM BPM V8.5.7 cumulative fix 2016.12 that allows an added row to be edited even if it has a column containing a DateTimePicker coach view that is bound to a Date simple type. To determine whether the cumulative fix is available and download it if it is, complete the following steps on Fix Central: 1. On the Select product tab, select WebSphere as the product group, IBM Business Process Manager with your edition from the WebSphere options, All as the installed version, and All as the platform, and then click Continue. 2. In the Text field, enter "cumulative fix", and click Continue.
Temporary fix
Comments
APAR Information
APAR number
JR56679
Reported component name
BPM ADVANCED
Reported component ID
5725C9400
Reported release
857
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-09-16
Closed date
2016-09-19
Last modified date
2016-10-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BPM ADVANCED
Fixed component ID
5725C9400
Applicable component levels
R857 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFTN5","label":"IBM Business Process Manager Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"857","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
15 October 2021