A fix is available
APAR status
Closed as program error.
Error description
LNKAUTH value is different than IPLPARM_LNKAUTH causing STIG rule AAMV0030 to be non-compliant.
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: Users of zSecure Admin/Audit exploiting the * * "System settings and software levels" report * * (newlist type SYSTEM) and users of zSecure * * Audit compliance testing framework * * exploiting STIG compliance rule AAMV0030. * **************************************************************** * PROBLEM DESCRIPTION: zSecure Admin/Audit generates an * * incorrect value for the LNKAUTH CARLa * * field (newlist type SYSTEM) causing the * * STIG rule AAMV0030 to be non-compliant. * **************************************************************** * RECOMMENDATION: Apply the PTF provided. * **************************************************************** When the LNKAUTH system initialization parameter is set to APFTAB, zSecure Admin/Audit reports the LNKAUTH field value (newlist type SYSTEM) incorrectly as 'Yes' when a dynamic link list is defined after an IPL. This also causes the STIG compliance rule AAMV0030 (LNKAUTH=APFTAB) to be non-compliant.
Problem conclusion
zSecure Admin/Audit has been modified so that it correctly reports the LNKAUTH system initialization parameter.
Temporary fix
Comments
APAR Information
APAR number
OA56113
Reported component name
ZSEC BASE,ADMIN
Reported component ID
5655T0100
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-08-31
Closed date
2018-09-17
Last modified date
2018-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA97423 UA97424 UA97425
Modules/Macros
CKROUOPT GKROUOPT
Fix information
Fixed component name
ZSEC BASE,ADMIN
Fixed component ID
5655T0100
Applicable component levels
R220 PSY UA97423
UP18/09/19 P F809
R221 PSY UA97424
UP18/09/19 P F809
R230 PSY UA97425
UP18/09/19 P F809
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSPQTM","label":"IBM Security zSecure Admin"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"LOB24","label":"Security Software"}}]