A fix is available
APAR status
Closed as program error.
Error description
ERROR DESCRIPTION:Ø When running the CKQCLEEF or CKQJLEEF jobs, the TERMINAL field is not added to the output of SMF Type 119 records although it is added for Type 118 records
Local fix
LOCAL FIX:Ø N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of zSecure Audit exploiting the * * software to prepare data for QRadar SIEM. * **************************************************************** * PROBLEM DESCRIPTION: The zSecure Audit QRadar SIEM interface * * does not generate the 'terminal' field * * for SMF records type 119. * **************************************************************** * RECOMMENDATION: Apply the PTF provided. * **************************************************************** The zSecure Audit QRadar SIEM interface does not generate the 'terminal' field for the following SMF records: - type 119 sub-type 2 written by TN3270E Telnet server; - types 118 and 119 (TCP/IP Statistics); - 'IP connection data of type 119 plus tunnels plus SSH logon fail; - type 118 sub-types 1 and 2 (TCP API initialization/termination);
Problem conclusion
The zSecure Audit QRadar SIEM interface has been modified so that the 'terminal' field is written to a QRadar LEEF file for the following SMF events: - type 119 sub-type 2 written by TN3270E Telnet server; - types 118 and 119 (TCP/IP Statistics); - 'IP connection data of type 119 plus tunnels plus SSH logon fail; - type 118 sub-types 1 and 2 (TCP API initialization/termination);
Temporary fix
Comments
APAR Information
APAR number
OA52576
Reported component name
ZSEC BASE,ADMIN
Reported component ID
5655T0100
Reported release
221
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-04-18
Closed date
2017-07-07
Last modified date
2017-08-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA92574
Modules/Macros
CKASMF77 CKQLEEF CKQLEEFL C2ELEEF GKRSMF77
Fix information
Fixed component name
ZSEC BASE,ADMIN
Fixed component ID
5655T0100
Applicable component levels
R221 PSY UA92574
UP17/07/13 P F707
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSPQTM","label":"IBM Security zSecure Admin"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"221","Edition":"","Line of Business":{"code":"LOB24","label":"Security Software"}}]