A fix is available
APAR status
Closed as program error.
Error description
When zSecure Collect parameter SUPPRESS=28 is specified to suppress message CKF028I, only the CKF028I message itself is suppressed. The continuation lines with details from the SVC 99 (DYNALLOC) completion are not suppressed.
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: Users of zSecure Collect exploiting the * * SUPPRESS command to suppress MSGCKF028I. * **************************************************************** * PROBLEM DESCRIPTION: zSecure Collect writes the continuation * * lines of MSGCKF0028I even if the * * message itself is suppressed by the * * SUPPRESS command. * **************************************************************** * RECOMMENDATION: Apply the PTF provided. * **************************************************************** When MSGCKF0028I is suppressed via the SUPPRESS= command, the first line of the message is suppressed but the continuation lines are not.
Problem conclusion
zSecure Collect has been modified so that MSGCKF0028I is fully suppressed when the SUPPRESS command specifies so. 1D0Y 1D1Y 210Y 211Y 220Y CKFALLOC
Temporary fix
Comments
APAR Information
APAR number
OA50002
Reported component name
ZSEC BASE,ADMIN
Reported component ID
5655T0100
Reported release
1D0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-02-24
Closed date
2016-03-09
Last modified date
2016-04-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA80940 UA80941 UA80942 UA80943 UA80944
Modules/Macros
CKFALLOC
Fix information
Fixed component name
ZSEC BASE,ADMIN
Fixed component ID
5655T0100
Applicable component levels
R1D0 PSY UA80940
UP16/03/10 P F603
R1D1 PSY UA80941
UP16/03/10 P F603
R210 PSY UA80942
UP16/03/10 P F603
R211 PSY UA80943
UP16/03/10 P F603
R220 PSY UA80944
UP16/03/10 P F603
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSPQTM","label":"IBM Security zSecure Admin"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1D0","Edition":"","Line of Business":{"code":"LOB24","label":"Security Software"}}]