A fix is available
APAR status
Closed as program error.
Error description
Odd problem where you can successfully run CARLa via CO.C and then typing GO or RUN when the CARLa code is entered. However, if you type SUB and try to run this via a batch process, the system on which the CARLa runs is excluded from the report. The CARLa being used is this alloc type=CKFREEZE active zsecsys=* NEWLIST type=ip_port name=PORTRESV, TT='Daliy Port Reservation Report', Emptylist=SHOW SORTLIST system end_port protocol count jobname resname bind options SUMMARY begin_port count(nd)
Local fix
Run via option CO.C
Problem summary
**************************************************************** * USERS AFFECTED: Users of zSecure Services for remote data * * access (CKNSERVE). * **************************************************************** * PROBLEM DESCRIPTION: zSecure Services for remote data access * * does not collect local system * * information when the ZSECSYS=* argument * * is spacified on the ALLOCATE CARLa * * statement. * **************************************************************** * RECOMMENDATION: Apply the PTF provided. * **************************************************************** When the ZSECSYS=* argument is specified in the ALLOCATE CARLa statement, the local system is excluded from processing, resulting in missing report(s) for the local system.
Problem conclusion
zSecure Services for remote data access have been modified so when ZSECSYS=* argument is provided for the ALLOCATE CARLa statement, the local system is also taken into account. Please note the documentation changes as provided by the APAR tracking comment data.
Temporary fix
Comments
APAR Information
APAR number
OA49724
Reported component name
ZSEC BASE,ADMIN
Reported component ID
5655T0100
Reported release
211
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-01-14
Closed date
2016-05-30
Last modified date
2016-06-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA81831 UA81832
Modules/Macros
CKNMAIN CKRMAIN CKROUZSN
Fix information
Fixed component name
ZSEC BASE,ADMIN
Fixed component ID
5655T0100
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSPQTM","label":"IBM Security zSecure Admin"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"211","Edition":"","Line of Business":{"code":"LOB24","label":"Security Software"}}]