A fix is available
APAR status
Closed as program error.
Error description
Added new CPC's to Policy and run INGAMS REFRESH to pick up the changes. The following errors occur: AOFA0000 Resolve error: No_HWOPER_task_defined AOF200I 10:38:22 : COMMAND INGRX830 FAILED. RECEIVED RETURN CODE 6 FROM INGHWCMD CPC300Z STATCOM There are enough HWOper's defined to handle the increase in CPC's.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All System Automation for z/OS customers of * * the releases V3.4 and V3.3, using the * * SA-BCPii to monitor and control System z * * mainframe processors. All customers of a * * GDPS service offering component, which * * requires the SA-BCPii of the named System * * Automation releases. * **************************************************************** * PROBLEM DESCRIPTION: During SA agent startup or INGAMS * * REFRESH processing, Clist INGRX830 may * * fail with a return code 6. As a result, * * not all SA-BCPii connections to the * * defined processors may become active, * * or can be activated later by the * * SA-BCPii connection monitor or the GDPS * * HMC monitor routine. * **************************************************************** * RECOMMENDATION: * **************************************************************** Hardware validation and monitoring Clist INGRX830 fails with RC 6. Required SA-BCPii connections may not be activated.
Problem conclusion
HWOPER tasks, which are actually assigned to a processor are fully initialized, supernumerous defined HWOPER tasks are started, but remain uninitialized. In case of an INGAMS REFRESH that adds processors to the configuration, such available HWOPER tasks fail to be fully initialized. As a result, the SA-BCPii session initialization for one or multiple processors may not function as expected, although the number of HWOPERs matches the number of the defined processors + 1, which is the required HWOPER task count. The following clists have been changed to make sure the HWOPER tasks, that wait to be assigned for work, are now initialized correctly: - INGRX805: HWOPER task initial clist. - INGRX810: SA-BCPii front end command. - INGRVX80: HW validation HW command handler.
Temporary fix
Comments
APAR Information
APAR number
OA45657
Reported component name
SYSTEM AUTO Z/O
Reported component ID
5698SA300
Reported release
340
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-07-16
Closed date
2014-08-19
Last modified date
2014-09-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA74586 UA74587
Modules/Macros
INGRVX80 INGRX805 INGRX810
Fix information
Fixed component name
SYSTEM AUTO Z/O
Fixed component ID
5698SA300
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWRCJ","label":"IBM Tivoli System Automation for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"340","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
03 September 2014