A fix is available
APAR status
Closed as new function.
Error description
After IMS V13 APAR PM85882 is applied, the IMS ACBGEN utility is corrected the behavior of the parameter BLDPSB=NO for: 1. FP DBD and shared secondary index 2. PSB should be rebuilt when BLDPSB=NO is specified and the DBD's physical structure is changed. This APAR enables the Advanced ACBGEN utility with the IMS V13 environment in which IMS APAR PM85882 is applied to process ACBGEN with BLDPSB=NO same as IMS ACBGEN utility with PM85882 does. Without this APAR, the Advanced ACBGEN utility with the IMS V13 environment will rebuild all the PSBs that referenced the FP DBD and shared secondary index whether DBD had a physical database structure changes or not.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IMS Library Integrity Utilities for z/OS, * * Version 2 Release 1 (FMID=H27P210) users * * who use the Advanced ACBGEN utility under * * IMS V13. * **************************************************************** * PROBLEM DESCRIPTION: By this APAR, the Advanced ACBGEN * * utility is corrected not to rebuild * * PSBs which references the DBD * * (including Full Function database, Fast * * Path DEDB, Fast Path secondary index, * * Full Function primary index, secondary * * index and shared secondary index * * databases) that does not have a * * physical database structure changes * * under IMS V13, when parameter BLDPSB=NO * * is specified on BUILD DBD= control * * statement in Advanced ACBGEN utility * * jobs. To enable this, Advanced ACBGEN * * need the IMS environment with the IMS * * APAR PM85882. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When parameter BLDPSB=NO was specified on BUILD DBD= control statement in Advanced ACBGEN utility without this APAR, all the PSBs that referenced the FP DB or shared secondary index DB were rebuilt whether DBD had a physical database structure changes or not. By this APAR, Advanced ACBGEN utility is corrected not to rebuild PSBs which references the DBD (including Full Function database, Fast Path DEDB, Fast Path secondary index, Full Function primary index, secondary index and shared secondary index databases) that does not have a physical database structure changes under IMS V13. Advanced ACBGEN utility will output same results as IMS ACBGEN does. To enable this, Advanced ACBGEN needs the IMS environment with the IMS APAR PM85882. If Advanced ACBGEN utility with this APAR runs in the IMS environment that does not have APAR PM85882 applied, the results has changed. PSBs will not be always rebuild when BLDPSB=NO is specified on the BUILD DBD=dbdname control statement and whether DBD had a physical database structure changes or not. This result is not expected results for BLDPSB=NO parameter. So apply IMS APAR PM85882 when this APAR will be applied. Advanced ACBGEN utility under IMS V10, V11 and V12 is not changed by this APAR.
Problem conclusion
Temporary fix
Comments
This APAR modifies the following modules to fix the problem. - FABQDRIV - FABQRLVD - FABQTASK
APAR Information
APAR number
PI08152
Reported component name
IMS LIBR INTEG
Reported component ID
5655I4200
Reported release
210
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-12-16
Closed date
2014-04-24
Last modified date
2014-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI17322
Modules/Macros
FABQDRIV FABQRLVD FABQTASK
Fix information
Fixed component name
IMS LIBR INTEG
Fixed component ID
5655I4200
Applicable component levels
R210 PSY UI17322
UP14/04/26 P F404
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Library Integrity Utilities"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}}]