A fix is available
APAR status
Closed as program error.
Error description
The 0C4 abend is occurring in EQQDPZMR +F2A, while performing loop analysis. In fact, this module is the one performing the loop analysis. Problem occurs, according to the provided offest, when it is checking if the LOOP control scanning the predecessors has ended with a match or if it needs to continue. It is in the loop detection module, while checking for the operation with: 480205 wkey_iadate 0401 wkey_iatime AI0MB3LATET wkey_adid 00000001 wkey_opno While scanning the PRED chain it found a predecessor operation which is actually an occurrence (it is a pending predecessor) and this is causing to get a not valid pointer (due to a different layout of the occurrence block, added with dataspace) considering it as an application dependency. this originated the S0C4. The mapping used is different if the DataSpace is enabled or not. That is why disabling the DataSpace the Abend does not occur. Problem is in 950 and in 930 code as well.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All 930 IWSz and 950 zWS users using the * * Data Space. * * FUNCTION=DP * **************************************************************** * PROBLEM DESCRIPTION: Abend S0C4 might occur when running the * * daily plan (any type) during the Loop * * Detection. * **************************************************************** An abend S0C4 might occur in Daily Plan (replan, extend, trial) during the Loop detection phase, when the Data Space feature is enabled. If the Data Space is disabled, under the same conditions no abend occurs.
Problem conclusion
Problem was due to a wrong check when scanning the predecessor chain and a pending predecessor is found in the loop.
Temporary fix
Comments
APAR Information
APAR number
PH21994
Reported component name
TIV WRKLD SCHD
Reported component ID
5697WSZ01
Reported release
950
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-02-10
Closed date
2020-03-25
Last modified date
2020-11-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI68608 UI68609
Modules/Macros
EQQDPZMR
Fix information
Fixed component name
TIV WRKLD SCHD
Fixed component ID
5697WSZ01
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSRULV","label":"IBM Workload Scheduler for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"950"}]
Document Information
Modified date:
13 November 2020