A fix is available
APAR status
Closed as program error.
Error description
We noticed that the SOAP-action sometimes is corrupted. It looks like the problem pops up when the DFHWS-SOAPACTION container exceeds 256 bytes.
Local fix
NA
Problem summary
**************************************************************** * USERS AFFECTED: All CICS Users * **************************************************************** * PROBLEM DESCRIPTION: When an outbound web service request is * * being made with an HTTP header larger * * than 256 bytes, this header becomes * * corrupted. * **************************************************************** If an HTTP header larger than 256 bytes is sent on an outbound web service request, this header is handled incorrectly when being copied into the send buffer. This is because a MVC instruction is used which can move a maximum of 256 bytes. A header larger than this will be truncated and result in a corrupt header being built.
Problem conclusion
DFHWBCL has been changed to ensure the entire HTTP header value is copied correctly.
Temporary fix
Comments
APAR Information
APAR number
PH21320
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
200
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-01-22
Closed date
2020-07-08
Last modified date
2020-08-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI70437 UI70438
Modules/Macros
DFHWBCL
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels