Error description
When customer runs dsntinst for tailoring second db2 installation jobs without exit DSNTINST, PANEL DSNTIPH will display the BSDS, Active Log and archive log data set names with the prefix of VCATALOG value, instead of from the correspondent fields from the original input member(from previoud version). This was reported in non data sharing running dsntinst in migrate mode.
Local fix
Exit the dsntinst completely, then rerun it for the second member
Problem summary
**************************************************************** * USERS AFFECTED: * * All Db2 12 for z/OS customers who run the * * Db2 installation or migration CLIST * * (DSNTINST). * **************************************************************** * PROBLEM DESCRIPTION: * * When a user completes an install * * or migrate CLIST session, and * * without exiting from the CLIST, * * starts another migrate CLIST * * session for a stand-alone Db2 * * system, the migration input names for * * the bootstrap, active log, and * * archive log data sets, as specified * * in the input parameter member (INPUT * * MEMBER NAME field on panel DSNTIPA1), * * are not maintained and displayed * * on panel DSNTIPH. They are replaced * * instead by names starting with the * * setting of the CATALOG ALIAS on panel * * DSNTIPA2 (VCATALOG input parameter). * **************************************************************** * RECOMMENDATION: * * Apply corrective PTF when available * **************************************************************** When a user completes an install or migrate CLIST session, and without exiting from the CLIST, starts another migrate CLIST session for a stand-alone Db2 subsystem, the migration input names for the bootstrap, active log, and archive log data sets, as specified in the input parameter member (INPUT MEMBER NAME field on panel DSNTIPA1), are not maintained and displayed on panel DSNTIPH. They are replaced instead by names starting with the setting of the CATALOG ALIAS on panel DSNTIPA2 (VCATALOG input parameter). These names are replaced because the variable VBSDSLGS, which is used by the CLIST DSNTINST to decide whether these names are replaced or not, still retains data from a previous CLIST session, as this variable is not reset when a new CLIST session starts.
Problem conclusion
In response, this APAR modifies DSNTINST so that VBSDSLGS is reset before the CLIST reads the input parameter member (INPUT MEMBER NAME) specified on panel DSNTIPA1.
Temporary fix
Comments
APAR Information
APAR number
PH20831
Reported component name
DB2 OS/390 & Z/
Reported component ID
5740XYR00
Reported release
C10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-01-08
Closed date
2020-03-26
Last modified date
2020-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI68659
Modules/Macros
DSNTINST
Fix information
Fixed component name
DB2 OS/390 & Z/
Fixed component ID
5740XYR00
Applicable component levels
RC10 PSY UI68659
UP20/04/03 P F004
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEPEK","label":"Db2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
04 May 2020