A fix is available
APAR status
Closed as program error.
Error description
1). CEXPUBMN S0C4 abend with PROGxx REFRPROT option enabled. this was caused by the setup of a cross memory post error exit routine. 2). Abend S052-516 in ETCON macro in module CEXMAPI+16F6 when IMS Connect V15 has the obsolete LOCAL port configured. ABEND0C4 ABENDS0C4 ABEND052 ABENDS052
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Connect Extensions V2.4 * **************************************************************** * PROBLEM DESCRIPTION: Miscellaneous Publisher API problems * **************************************************************** * RECOMMENDATION: * **************************************************************** 1. CEXPUBMN S0C4 abend with PROGxx REFRPROT option enabled. This was caused by the setup of a cross memory post error exit routine. 2. Abend S052-516 in ETCON macro in module CEXMAPI+16F6 when IMS Connect V15 has the obsolete LOCAL port configured.
Problem conclusion
1. Replace the use of cross memory post with the safe cross memory post IEAMSXMP which does not require an error exit. 2. Correct logic error when LOCAL ports are configured.
Temporary fix
Comments
APAR Information
APAR number
PH19033
Reported component name
IMS CONNECT EXT
Reported component ID
5655K4800
Reported release
240
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-11-08
Closed date
2019-12-13
Last modified date
2020-01-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI66996 PH20525
Modules/Macros
CEXAPEQU CEXAPMT1 CEXCONSP CEXIICB CEXMAPI CEXMSGT CEXPC01 CEXPUBMN
Fix information
Fixed component name
IMS CONNECT EXT
Fixed component ID
5655K4800
Applicable component levels
R240 PSY UI66996
UP19/12/19 P F912
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Connect Extensions"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.4.0"}]
Document Information
Modified date: