APAR status
Closed as program error.
Error description
z/OS Debugger service for IBM Developer for z Systems Enterprise Edition 14.0.0.9 IBM Developer for z Systems 14.0.0.9 IBM Debug for z Systems 14.0.0.9 --- Service --- -IBM Developer for systems Z debugger V14 gets ABEND ABENDS0C1 branching into address '00000000' from EQATIEXT with IMS isolation (ISO) feature. The ABEND happens in DT module EQATIEXT when calling the clients DFSMSCE0 for INIT. While the client's DFSMSCE0 does not have INIT entry point registered/defined, VINIT in the vector table is set to NULL, and EQATIEXT still branch to it, thus the ABEND. (PH08226 at 14.1) -The cross reference table data set is read in a non-IMS environment. (PH09204 at 13.1) -ISPF RESTORE request error ISPP147 after IBM Developer for System z debugger ISPF Edit command EQAJCL T CMD and exiting ISPF Edit session. ISPP147: RESTORE request error A CONTROL RESTORE service request was issued for which there was no matching CONTROL SAVE. (PH10319 at 14.0) -ABENDS0C4 in EQA00OHH when application is doing Binder API calls and running with SVC Screening on. Debugging running in SVC Screening mode catches the binder module in Access Mode which causes the abend. The debugger should ignore Access Mode callers. (PH12444 at 13.1) --- End Service ---
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * z/OS Debugger 14.0 users who have the problems described in * * the Problem Description. * **************************************************************** * PROBLEM DESCRIPTION: * * z/OS Debugger service for * * IBM Developer for z Systems * * Enterprise Edition 14.0.0.9 * * IBM Developer for z Systems 14.0.0.9 * * IBM Debug for z Systems 14.0.0.9 * * * * --- Service --- * * * * -IBM Developer for systems Z debugger * * V14 gets ABEND ABENDS0C1 branching * * into address '00000000' from EQATIEXT * * with IMS isolation (ISO) feature. * * * * The ABEND happens in DT module * * EQATIEXT when calling the clients * * DFSMSCE0 for INIT. While the client's * * DFSMSCE0 does not have INIT entry * * point registered/defined, VINIT in * * the vector table is set to NULL, and * * EQATIEXT still branch to it, thus the * * ABEND. * * (PH08226 at 14.1) * * * * -The cross reference table data set is * * read in a non-IMS environment. * * (PH09204 at 13.1) * * * * -ISPF RESTORE request error ISPP147 * * after IBM Developer for System z * * debugger ISPF Edit command EQAJCL T * * CMD and exiting ISPF Edit session. * * ISPP147: * * RESTORE request error * * A CONTROL RESTORE service request was * * issued for which there was no * * matching CONTROL SAVE. * * (PH10319 at 14.0) * * * * -ABENDS0C4 in EQA00OHH when * * application is doing Binder API calls * * and running with SVC Screening on. * * Debugging running in SVC Screening * * mode catches the binder module in * * Access Mode which causes the abend. * * The debugger should ignore Access * * Mode callers. * * (PH12444 at 13.1) * * * * --- End Service --- * **************************************************************** * RECOMMENDATION: * * Installations that need these problem fixes should install * * this service. * **************************************************************** Miscellaneous service.
Problem conclusion
Service is available.
Temporary fix
Comments
APAR Information
APAR number
PH16754
Reported component name
ZOS DEBUGGER
Reported component ID
5724T0713
Reported release
E00
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-09-11
Closed date
2019-09-24
Last modified date
2019-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI65462
Modules/Macros
EQALDR31 EQADCVSA EQADCCN0 EQAS0OHH EQA00EHI EQAEVDBG EQA00STU EQA00XML EQA10PRC EQAS0NMU EQA00EHB EQAS0BND EQATIEDT EQANCHAB EQATIEXT EQACIC51 EQASG006 EQANISET EQAS0OHT EQAS0OHV EQATIEX2 EQAS0MVS EQAL6Z3 EQAL6Z6 EQA10MVS EQAW3Z3 EQAMVS31 EQAW3Z6 EQANCREL EQAS0A64 EQA0AIP2 EQA00CND EQAAFSPS EQADCMGR EQA10DTL EQAS0DTL EQAS0EVH EQA00SVC EQAYBGID EQA00ABE EQA00AEI EQACIC32 EQA0SDTL EQANICTL EQAS0DEI EQADCTSQ EQANMDBG EQACTL EQA00OHT EQAEV006 EQANBSWT EQA00CIC EQA00OHV EQA01SVC EQA0SRQ4 EQACMDRV EQA00FA EQACIC41 EQANCABE EQA00OHE EQAS0EHI EQA01SV2 EQA00OHH EQA00OHI EQAJCL EQA00OHL EQAS0EHB EQA00LIS EQA00NMU EQAZPCM EQA00BND EQA0SCHG EQA00CHG EQA00DEI EQAMVS64 EQAIIRMG EQASAIP2 EQA0SCL2 EQA0SCL1 EQAXPL31 EQANIAFE EQANICRT EQAD3XXT EQANCLDE EQAYBCNM EQAYSMMN EQALDR64 EQA0CINF EQANCFRM EQANIPSB EQAS0ABE EQA00MEM EQA00EVH EQA00DLD EQA00DTL EQALMA EQAS0CND EQA00A64 EQADCREP EQAYFGID EQA0SRP1 EQAYLIST EQA0SRP2 EQA00BPP EQA0SRP4
Fix information
Fixed component name
ZOS DEBUGGER
Fixed component ID
5724T0713
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSJK49","label":"IBM Developer for z Systems"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"E00"}]
Document Information
Modified date:
24 June 2022