A fix is available
APAR status
Closed as program error.
Error description
HEXLOC table with OFFSET compile option gives incorrect offsets
Local fix
use LIST option instead of OFFSET compile option
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.2 who compile * * with the OFFSET and TEST option. * **************************************************************** * PROBLEM DESCRIPTION: Incorrect output: The hex offset values * * in the text produced by the OFFSET * * option in thecompiler listing are * * incorrect. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** Compiler internal statement location information was incorrectly associated with the adjacent COBOL verb.
Problem conclusion
The compiler was updated to produce the correct hex offset values in the text produced by the OFFSET option.
Temporary fix
Comments
APAR Information
APAR number
PH15778
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-08-16
Closed date
2019-09-18
Last modified date
2019-11-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI65366 UI65367 UI65368 PH19228
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOPI IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UI65366
UP19/09/21 P F909
R621 PSY UI65367
UP19/09/21 P F909
R622 PSY UI65368
UP19/09/21 P F909
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023