Error description
A format 3 "DIVIDE id1 BY nnn GIVING id2 REMAINDER id3" when id1 and id2 point to the same variable gives the wrong remainder under ARCH(12), but works correctly under ARCH(11). DIVIDE W-CH-SUM BY 10 GIVING W-CH-SUM REMAINDER W-CH-REMAINDER When id1 and id2 are the same data item, the remainder value is incorrect under ARCH(12). When id2 and id2 are not the same data item, the remainder is always correct.
Local fix
Compile under ARCH(11) or below.
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.2, compiling * * programs at ARCH(12) that contain a DIVIDE * * with REMAINDER where the dividend and * * quotient are the same data item. * **************************************************************** * PROBLEM DESCRIPTION: The remainder incorrectly contains the * * same value as the quotient. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** When calculating the remainder, the compiler loaded the value of the dividend after calculating the quotient. Since the dividend and quotient use the same data item, this loads the quotient, not the dividend, before specifying the remainder.
Problem conclusion
The compiler is fixed to generate the correct remainder value.
Temporary fix
Comments
APAR Information
APAR number
PH14291
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-07-09
Closed date
2019-09-18
Last modified date
2019-10-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOPI IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UI65366
UP19/09/21 P F909
R621 PSY UI65367
UP19/09/21 P F909
R622 PSY UI65368
UP19/09/21 P F909
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023