When running a task that creates and accesses large numbers of view private files in parallel in an IBM Rational ClearCase dynamic view, the ClearCase host may crash reporting an error in mvfs100x64.sys. The dump will report this as a "CACHE_MANAGER" dump.
Local fix
Disable the MVFS cache manager by setting the following registry value to 0: HKLM\system\Currentcontrolset\services\mvfs\Parameters\UseCacheM anager. Then reboot the host. This should eliminate the crash, but may degrade MVFS performance.
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of ClearCase on Microsoft Windows * **************************************************************** * PROBLEM DESCRIPTION: * * The ClearCase client host may crash with code CACHE_MANAGER * * (34), during activities which generate concurrent I/O * * operations on files in ClearCase dynamic views. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
This problem is fixed in ClearCase 9.0.1.8.
Temporary fix
Comments
APAR Information
APAR number
PH13593
Reported component name
CLEARCASE WIN
Reported component ID
5724G2900
Reported release
901
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-06-19
Closed date
2019-09-23
Last modified date
2019-09-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CLEARCASE WIN
Fixed component ID
5724G2900
Applicable component levels
R901 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSSH27","label":"Rational ClearCase"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"901","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
17 October 2021