A fix is available
APAR status
Closed as program error.
Error description
Autonomics Director client sends Query Monitor command to AD server to get monitor list. AD server sends it to AD client every 126 databases. If there are over 127 databases, AD server sends 2 segments. At that time, AD server sets wrong values to control block for multi-segment. As a result, AD client can get only last segment and does not show enough information for Monitor list.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of the Autonomics Director. * **************************************************************** * PROBLEM DESCRIPTION: Enough information for Monitor list * * could not be displayed on Autonomics * * Director client. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR and * * restart Autonomics Director server. * **************************************************************** Autonomics Director client sends Query Monitor command to AD server to get monitor list. AD server sends database information of Monitor list to AD client. If there are a lot of database information, AD server divides them to some segments and sends them to AD client. AD server sets wrong values to control block for multi-segment. As a result, AD client gets only last segment and does not show enough information for Monitor list.
Problem conclusion
The following program has been fixed to set appropriate value to control block for multi-segment. - IAVUXMQ
Temporary fix
Comments
APAR Information
APAR number
PH12645
Reported component name
IMS TOOLS BASE
Reported component ID
5655V9300
Reported release
160
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-05-30
Closed date
2019-06-11
Last modified date
2019-07-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI63553
Modules/Macros
IAVUXMQ
Fix information
Fixed component name
IMS TOOLS BASE
Fixed component ID
5655V9300
Applicable component levels
R160 PSY UI63553
UP19/06/13 P F906
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.