PH12164: CICS 5.5 PLT PROCESSING DOES NOT PERFORM SYNTAX OR ERROR CHECKING

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • You migrate to CICS 5.5, which no longer supports assembled
    PLTPI or PLTSD programs. At 5.5, CICS uses an interpretative
    process to read the source code for the PLT programs. This
    process was originally implemented with no syntax checking and
    no error messages.
    This APAR is being opened to implement proper syntax checking
    during the interpretation of the PLT source and produce new
    error messages if errors are found.
    .
    .
    Additional Symptom(s) Search Keyword(s): KIXREVGJT
    

Local fix

  • Assemble source using pre-5.5 libraries to perform syntax
    checking before using PLT source in a 5.5 environment
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Incorrectly coded PLT (Program List     *
    *                      Table) entries may be ignored without   *
    *                      warning.                                *
    ****************************************************************
    When processing the PLT, program entries can be ignored when not
    part of a correctly spelled PROGRAM=progname entry. There is no
    warning message to highlight this.
    

Problem conclusion

  • CICS will check that the PLT entry contains 'PROGRAM='.
    Unrecognised entries will result in new message DFHAP2000I.
    The following new message will be added to the CICS TS 5.5
    Messages and Codes manual:
    
    DFHAP2000I applid Unrecognized statement found in program list
    table (PLT). The statement is:  pltdata
    System Action:
    CICS continues to validate entries in the PLT.
    User Response:
    Check that the statements in the PLT and in any copied members
    are valid.
    
    Module: DFHAPTB
    
    XMEOUT parameters/Message inserts:
    1. applid
    2. pltdata
    
    Destination: Console
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH12164

  • Reported component name

    CICS TS Z/OS V5

  • Reported component ID

    5655Y0400

  • Reported release

    200

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-05-16

  • Closed date

    2019-11-08

  • Last modified date

    2019-11-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI66339

Modules/Macros

  • DFHAPTB  DFHMEAPC DFHMEAPE DFHMEAPK
    

Fix information

  • Fixed component name

    CICS TS Z/OS V5

  • Fixed component ID

    5655Y0400

Applicable component levels

  • R200 PSY UI66339

       UP19/11/09 P F911

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.5","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.5","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
30 November 2019