A fix is available
APAR status
Closed as program error.
Error description
This APAR fixes a compiler introduced error during Debug Tool and z/OS Debugger debugging, specifically when attempting to STEP OVER a PERFORM statement
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.2 who * * compile their programs with the Enterprise * * COBOL V6.2 November 2018 PTF with the TEST * * option and use IBM Debug Tool or IBM z/OS * * Debugger and issue the STEP OVER action on * * a PERFORM statement. * **************************************************************** * PROBLEM DESCRIPTION: Issuing a STEP OVER action on a COBOL * * PERFORM statement using IBM Debug Tool * * or IBM z/OS Debugger may result in * * skipping 2 lines instead of one. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** The Enterprise COBOL V6.2 November 2018 PTF contained new function that inadvertently changed the behavior of the STEP OVER debug action. This behavior is fixed with this PTF.
Problem conclusion
The compiler was updated so that the correct behavior of the STEP OVER action on a PERFORM statement in the debugger has been restored.
Temporary fix
Comments
APAR Information
APAR number
PH06193
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-12-05
Closed date
2018-12-09
Last modified date
2019-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOPI IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UI60153
UP18/12/14 P F812 {
R621 PSY UI60154
UP18/12/14 P F812 {
R622 PSY UI60155
UP18/12/14 P F812 {
R62H PSY UI60156
UP18/12/14 P F812 {
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023