IBM Support

PH05479: ABEND S0C4 FUNSCRUB+X'570'

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • 1. Scrub of IMS x'5920' record can abend S0C4 at offset x'570'.
    This occurs due to a misinterpretation the meaning of flag bit
    MSUPRLOC.
    2. Invalid interpretation of the length field MSUPLEN when the
    field type is MSUPDEC.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM Common Services Library VA10    *
    ****************************************************************
    * PROBLEM DESCRIPTION: Abend S0C4 FUNSCRUB+x'570'              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    1. Scrub of IMS x'5920' record can abend S0C4 at offset x'570'.
       This occurs due to a misinterpretation the meaning of flag
       bit MSUPRLOC.
    
    2. Invalid interpretation of the length field MSUPLEN when the
       field type is MSUPDEC.
    

Problem conclusion

  • 1. The value of flag bit MSUPRLOC is no longer used in
       determining the IMS x'5920' record format.
    
    2. The value in MSUPLEN is now interpreted correctly for the
       MSUPDEC case.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH05479

  • Reported component name

    FUNC SUPP LIBRA

  • Reported component ID

    5655K4801

  • Reported release

    A10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-11-19

  • Closed date

    2019-02-15

  • Last modified date

    2019-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI61326

Modules/Macros

  •    FUNSCRBC FUNSCRBD FUNSCRBE FUNSCRBF
    

Fix information

  • Fixed component name

    FUNC SUPP LIBRA

  • Fixed component ID

    5655K4801

Applicable component levels