Error description
RTC item 102308. A large trace can easily have over a million entries. The index to reference the entries is only 6 digits so when it goes over 999999, the next entry is identified as 000000 ( it wraps ). Not only is this confusing, it breaks some formatting tools.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS users. * **************************************************************** * PROBLEM DESCRIPTION: Trace entry sequence numbers are capped * * at 6 digits. * **************************************************************** This problem presents when processing a CICS trace that contains more than 999999 entries. The next trace entry sequence (entry_num) after 999999 will be 000001 and subsequent trace entries will increment until 999999 is reached. This behaviour will repeat until all the trace entries in the trace table are processed. When this occurs, the output presented to the user will have instances of trace entry numbers (by entry_num) containing different trace entries. Dump formatting tools which select trace entries by an entry_num range will only select the first instance.
Problem conclusion
Dump formatting code has been amended to increase the entry_num range of a CICS trace from 999999 to 9999999. The Knowledge Center will be amended. The KC references IBM supplied tool DFHTUxxx, DFHPDxxx and DFHDUxxx which are all capable of formatting CICS trace entries. The detailed syntax only appears against DFHTUxxx (with DFHPDxxx and DFHDUxxx referring to DFHTUxxx). The description of the trace entry index ( entry_num ) contain 6 character representations of entry_num thus: nnnnnn, 999999, and xxxxxx-yyyyyy. These will be amended to: nnnnnnn, 9999999 and xxxxxxx-yyyyyyy respectively
Temporary fix
Comments
APAR Information
APAR number
PH03960
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-10-11
Closed date
2019-01-30
Last modified date
2019-03-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI61022 UI61023 UI61024 UI61025 UI61026
Modules/Macros
DFHTRDUF DFHTRFFE DFHTRFPP DFHTRPRA
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R000 PSY UI61026
UP19/02/02 P F902
R100 PSY UI61025
UP19/02/02 P F902
R200 PSY UI61022
UP19/02/09 P F902
R800 PSY UI61024
UP19/02/05 P F902
R900 PSY UI61023
UP19/02/02 P F902
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
01 March 2019