IBM Support

PH03148: IEC143I 213-30 IF TWO SELECT STATEMENTS SHARE THE SAME OUTPUT PDS... INCLUDED IN PTF UI58908

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • PB53894
    PB53950
    PB54032
    IEC143I 213-30 if two select statements share the same output
    PDS
    
    An allocation error occurs for one of the output data sets of a
    multiple SELECT unload command.
    The following error messages are issued:
    IEC143I 213-30,IFG0194D,HPUZ475R,REPRO,UL02,0AC7,INF006,  294
    LABO.HPUZ0475.OUTDATA(UL02)
    
    
    This occurs if at least two SELECT statements fullfil the
    following conditions:
    - their output data sets (défined through OUTDDN) are members of
    the same PDS data set.
    - the tables belong to the same tablespace or the parallelism is
    activated either for lds read in native mode, eitherfor SQL
    unload in SQL mode
    

Local fix

  • Separate the SELECT statements that share the same output PDS
    into separate UNLOAD commands
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM Db2 High Performance Unload     *
    *                 z/OS.                                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: An allocation error occurs for one of   *
    *                      the output data sets of a multiple      *
    *                      SELECT unload command.                  *
    *                      The following error messages are        *
    *                      issued:                                 *
    *                      IEC143I 213-30,IFG0194D,HPUZ475R,REPRO  *
    *                      ,UL02,0AC7,INF006,  294                 *
    *                      LABO.HPUZ0475.OUTDATA(UL02)             *
    *                      ...                                     *
    *                      SYSTEM COMPLETION CODE=213  REASON      *
    *                       CODE=00000030                          *
    *                       TIME=14.18.54  SEQ=52030  CPU=0000     *
    *                        ASID=0065                             *
    *                       PSW AT TIME OF ERROR  075C1000         *
    *                         80DDF36E  ILC 2  INTC 0D             *
    *                         NO ACTIVE MODULE FOUND               *
    *                         NAME=UNKNOWN                         *
    *                         DATA AT PSW  00DDF368 - 4100302C     *
    *                        0A0D010D  A7E5014B                    *
    *                         AR/GR 0: 008C1CF0/00000000_00DDF678  *
    *                         1: 00000000/00000000_A4213000        *
    *                         2: 00000000/00000048_0000B9C0        *
    *                         3: 00000000/00000000_00DDF64C        *
    *                         4: 00000000/00000000_008BD410        *
    *                         5: 00000000/00000000_008BD7A4        *
    *                         6: 20C7CA00/00000000_008BD74C        *
    *                         7: E9D3D6C7/00000000_008BD7A4        *
    *                         8: 00000000/00000000_008BD76C        *
    *                         9: 00000000/00000048_008BAEC0        *
    *                         A: 00000000/00000048_80DE1A0A        *
    *                         B: 00000000/00000000_00DE25CA        *
    *                         C: 00000000/00000000_80DE2826        *
    *                         D: 00000000/00000000_7F517CE8        *
    *                         E: 00000000/00000000_80DDEBCC        *
    *                         F: 00000000/00000000_00000030        *
    *                       END OF SYMPTOM DUMP                    *
    *                      This occurs if at least two SELECT      *
    *                      statements fullfil the following        *
    *                      conditions:                             *
    *                      -their output data sets (d fined        *
    *                       through OUTDDN) are members of the     *
    *                       same PDS data set.                     *
    *                      -the tables belong to the same          *
    *                       tablespace or the parallelism is       *
    *                       activated either for lds read in       *
    *                       native mode, either for SQL            *
    *                       unload in SQL mode                     *
    *                      Example: The following unload faces     *
    *                       this issue.                            *
    *                       //UL01     DD DSN=LABO.HPUZ0475        *
    *                        .OUTDATA(UL01),DISP=SHR               *
    *                       //UL02     DD DSN=LABO.HPUZ0475        *
    *                        .OUTDATA(UL02),DISP=SHR               *
    *                       //SYSIN    DD *                        *
    *                        UNLOAD TABLESPACE                     *
    *                        DB2 NO                                *
    *                         SELECT * FROM MZLFRD.TBDZBAFRD00601  *
    *                        OUTDDN UL01                           *
    *                        SELECT * FROM MZLFRD.TBDZBAFRD00601   *
    *                        OUTDDN UL02                           *
    *                        ;                                     *
    *                      pb54032                                 *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    The oddn module was changed.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH03148

  • Reported component name

    DB2 HI PERF UNL

  • Reported component ID

    5697F4400

  • Reported release

    430

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-09-21

  • Closed date

    2018-10-11

  • Last modified date

    2018-12-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI58959

Modules/Macros

  •    INZUTILK
    

Fix information

  • Fixed component name

    DB2 HI PERF UNL

  • Fixed component ID

    5697F4400

Applicable component levels

  • R430 PSY UI58959

       UP18/11/02 P F811

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUUV","label":"IBM Db2 High Performance Unload for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: