Error description
With NOTEST(DWARF,SOURCE) in V6, some xref info that is needed is not present in the DWARF data. Specifically: 1) DW_AT_IBM_xref_coord in DW_TAG_variable DIE. 2) .debug_xref section. FA is deprecated by excluding data fields in the event detail and COBOL Explorer is no longer functional. This problem does not exist with TEST(DWARF,SOURCE) in V6.
Local fix
Compile with TEST(DWARF).
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.2 who compile * * with the NOTEST(DWARF) compiler option and * * try to use XREF information from the DWARF * * debugging data (in particular, Fault * * Analyzer needs this info). * **************************************************************** * PROBLEM DESCRIPTION: There is no XREF information in the * * DWARF debugging data with * * NOTEST(DWARF), unlike with TEST(DWARF). * **************************************************************** * RECOMMENDATION: Apply provided PTF and recompile. * **************************************************************** When the NOTEST(DWARF) option was added to COBOL V6.2, the compiler did not add ALL of the debugging data to the DWARF output.
Problem conclusion
The compiler was changed to put XREF information out in the DWARF debugging data with NOTEST(DWARF). In addition, some improved compile time optimization was incidentally made for customers who compile with TEST(NODWARF).
Temporary fix
Comments
×**** PE18/12/05 FIX IN ERROR. SEE APAR PH06193 FOR DESCRIPTION
APAR Information
APAR number
PH03038
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-09-19
Closed date
2018-11-22
Last modified date
2018-12-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI59885 UI59886 UI59887 UI59888
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOPI IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UI59885
UP18/11/29 P F811
R621 PSY UI59886
UP18/11/29 P F811
R622 PSY UI59887
UP18/11/29 P F811
R62H PSY UI59888
UP18/11/29 P F811
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023