A fix is available
APAR status
Closed as new function.
Error description
If the customer has Recovery Solution Pack registered, RECOVERY sensor and evaluation jobs are performed automatically. However the customer would like to run only REORG sensor and evaluation jobs. We will provide new feature to disable RECOVERY automation.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of the Autonomics Director. * **************************************************************** * PROBLEM DESCRIPTION: If the customer has Recovery * * Solution Pack registered, * * RECOVERY sensor and evaluation * * are performed automatically. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** If the customer has Recovery Solution Pack registered, RECOVERY sensor and evaluation jobs are performed automatically. However the customer would like to run only REORG sensor and evaluation jobs.
Problem conclusion
The Autonomics Director provides new parameter. If user specifies RECOVERY=DISABLE, recovery sensor and evaluation will not be performed automatically. 1. ADD 'RECOVERY=DISABLE' parameter to IAVPCOM member in your PROCLIB like as below. XCFGROUP=adm00, ITKBGROUP=srvrname, WLMRINT=0, RACFAPPL=adracf, RECOVERY=DISABLE, JCLLIB=yourhlq.JCLLIB 2. Start the Autonomics Director server. The following job log messages indicate that recovery sensor and evaluation will not be performed automatically. IAV0704I - RECOVERY SENSOR AND EVALUATION AUTOMATION IS DISABLED New parameter is: RECOVERY (Optional) Specify the Recovery sensor and evaluation automation enable and disable. You can set this parameter to ENABLE and DISABLE. The default value is ENABLE. If you set DISABLE, Recovery sensor and evaluation will not be performed automatically. New Message is: IAV0704I RECOVERY SENSOR AND EVALUATION AUTOMATION IS DISABLED Explanation: The Autonomics Director environment has IMS Recovery Solution Pack. However Recovery sensor and evaluation jobs will not be performed automatically. System action: Processing continues. User response: None.
Temporary fix
Comments
APAR Information
APAR number
PH01825
Reported component name
TOOLS BASE
Reported component ID
5655V9300
Reported release
160
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2018-08-16
Closed date
2018-08-28
Last modified date
2019-05-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI58083
Modules/Macros
IAVD0ENU IAVDOCDR IAVDPLP0 IAVDSTIM
Fix information
Fixed component name
TOOLS BASE
Fixed component ID
5655V9300
Applicable component levels
R160 PSY UI58083
UP18/08/31 P F808