Fixes are available
APAR status
Closed as program error.
Error description
Application crashes at start up on iOS 5.1.1 devices with the following error: Dyld Error Message: Symbol not found: _OBJC_CLASS_$_UICollectionViewCell Referenced from: /var/mobile/Applications/XXXXXXXX-XXXX-XXXX-XXXX-XXXXXXXXXXXX/Ap plicationName.app/ApplicationName Expected in: /System/Library/Frameworks/UIKit.framework/UIKit in /var/mobile/Applications/XXXXXXXX-XXXX-XXXX-XXXX-XXXXXXXXXXXX/Ap plicationName.app/ApplicationName Dyld Version: 199.6 This works fine with iOS 6.0 and later. A work around was provided in PI19612 that enables developers to remove the Tealeaf library. This APAR (PI19847) provides a further solution for applications that use the Tealeaf library with Worklight on iOS 5.1.1.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users running hybrid iOS applications created with Worklight * * 6.0.0.2 on iOS 5.x. * **************************************************************** * PROBLEM DESCRIPTION: * * Worklight 6.0.0.2 includes a version of the Tealeaf library * * that is not compatible with iOS 5.x, causing the application * * to crash. * **************************************************************** * RECOMMENDATION: * * - * **************************************************************** -
Problem conclusion
This fix includes a version of the Tealeaf library that is compatible with iOS 5.x.
Temporary fix
Either remove the Tealeaf library (Worklight v6.0.0.2 with APAR PI19612 applied) or don't enable the Analytics optional feature (Worklight v6.1).
Comments
APAR Information
APAR number
PI19847
Reported component name
WORKLIGHT CONSU
Reported component ID
5725I4301
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-06-11
Closed date
2014-06-13
Last modified date
2014-06-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WORKLIGHT CONSU
Fixed component ID
5725I4301
Applicable component levels
R600 PSY
UP
R610 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"600","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
17 October 2021