Error description
Initial WL app on device with busy indicator showing and then direct update notification comes; update the app and after update finishes, the busy indicator is still showing and does not hide, which makes the app hanging on the page and stops the app and customer to the next steps. This problem happens every time on both android and iOS and different types of mobile devices.
Local fix
Add the following code at the end of busyIndicatorShowApp.js: ---------------------------------------------------------------- var _wl_update = WL.App.__update; WL.App.__update = function(shouldUpdateSilently) { busy.hide(); _wl_update.bind(WL.App)(shouldUpdateSilently); }; ----------------------------------------------------------------
Problem summary
**************************************************************** * USERS AFFECTED: * * Developers are not notified that a direct update process is * * about to begin. * **************************************************************** * PROBLEM DESCRIPTION: * * Worklight client doesn't send notifications that a direct * * update process is about to begin and therefore are unable to * * take custom actions (like hide a busy indicator). * **************************************************************** * RECOMMENDATION: * * - * ****************************************************************
Problem conclusion
The problem is fixed by firing a custom event WL.Events.BEFORE_DIRECT_UPDATE, which can be handled at the document level ($(document).on(WL.Events.BEFORE_DIRECT_UPDATE, function() {....}).
Temporary fix
Comments
APAR Information
APAR number
PI19673
Reported component name
WORKLIGHT CONSU
Reported component ID
5725I4301
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-06-09
Closed date
2014-06-18
Last modified date
2014-06-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WORKLIGHT CONSU
Fixed component ID
5725I4301
Applicable component levels
R600 PSY
UP
R610 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"600","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
17 October 2021