Fixes are available
Rational ClearCase Fix Pack 6 (8.0.1.6) for 8.0.1
Rational ClearCase Fix Pack 13 (8.0.0.13) for 8.0
Rational ClearCase Fix Pack 14 (8.0.0.14) for 8.0
Rational ClearCase Fix Pack 7 (8.0.1.7) for 8.0.1
Rational ClearCase Fix Pack 15 (8.0.0.15) for 8.0
Rational ClearCase Fix Pack 8 (8.0.1.8) for 8.0.1
Rational ClearCase Fix Pack 16 (8.0.0.16) for 8.0
Rational ClearCase Fix Pack 9 (8.0.1.9) for 8.0.1
Rational ClearCase Fix Pack 17 (8.0.0.17) for 8.0
Rational ClearCase Fix Pack 10 (8.0.1.10) for 8.0.1
Rational ClearCase Fix Pack 18 (8.0.0.18) for 8.0
Rational ClearCase Fix Pack 11 (8.0.1.11) for 8.0.1
Rational ClearCase Fix Pack 19 (8.0.0.19) for 8.0
Rational ClearCase Fix Pack 12 (8.0.1.12) for 8.0.1
Rational ClearCase Fix Pack 20 (8.0.0.20) for 8.0
Rational ClearCase Fix Pack 13 (8.0.1.13) for 8.0.1
Rational ClearCase Fix Pack 21 (8.0.0.21) for 8.0
Rational ClearCase Fix Pack 14 (8.0.1.14) for 8.0.1
Rational ClearCase Fix Pack 15 (8.0.1.15) for 8.0.1
Rational ClearCase Fix Pack 16 (8.0.1.16) for 8.0.1
Rational ClearCase Fix Pack 17 (8.0.1.17) for 8.0.1
Rational ClearCase Fix Pack 18 (8.0.1.18) for 8.0.1
Rational ClearCase Fix Pack 19 (8.0.1.19) for 8.0.1
Rational ClearCase Fix Pack 20 (8.0.1.20) for 8.0.1
Rational ClearCase Fix Pack 21 (8.0.1.21) for 8.0.1
Rational ClearCase Fix Pack 22 (8.0.1.22) for 8.0.1
Rational ClearCase Fix Pack 23 (8.0.1.23) for 8.0.1
Rational ClearCase Fix Pack 24 (8.0.1.24) for 8.0.1
Rational ClearCase Fix Pack 25 (8.0.1.25) for 8.0.1
APAR status
Closed as program error.
Error description
When working in IBM Rational ClearTeam Explorer (CTE), you attempt to an option at the bottom of the CTE checkin preferences dialog window. You will see that the option is not visible because the dialog window is truncated and the scroll bar will not scroll to the bottom of the dialog window. WORKAROUND: Expand the 'Checkin Dialog Preferences' window so that the 'Only include the physical files selected for checkin' option is visible again. The scroll bar on the right hand side still remains. Reduce the preferences window again so the option is no longer visible, and the scroll bar on the right hand side is still there. This time, you can scroll all the way to the bottom. When you do, you see the option.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of IBM Rational ClearTeam Explorer. * **************************************************************** * PROBLEM DESCRIPTION: * * When working in IBM Rational ClearTeam Explorer (CTE), * * options at the bottom of the CTE checkin preferences dialog * * window are not visible because the dialog window is * * truncated and the scroll bar will not scroll to the bottom * * of the dialog window. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
A fix is available in ClearCase versions 8.0.0.13 and 8.0.1.6
Temporary fix
Comments
APAR Information
APAR number
PI18999
Reported component name
CLRCASE MSITE W
Reported component ID
5724G3200
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-05-30
Closed date
2014-12-11
Last modified date
2014-12-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CLRCASE MSITE W
Fixed component ID
5724G3200
Applicable component levels
R800 PSY
UP
R801 PSY
UP
Document Information
Modified date:
14 October 2021