APAR status
Closed as program error.
Error description
SA has scrolled the diagram as intended but then no longer thinks the diagram has scrolled after a symbol definition has been edited. When the user next attempts to interact with the diagram there are unexpected effects - in the first case triggering the rename of the symbol. I have repeated the problem. you can trigger it using the scrollbars: 1) Lay out a diagram as the client did 2) Zoom in so not all symbols are visible, remember where symbols are with the diagram view at the top left of the diagram. 3) Scroll down so the last symbol is selected 4) Edit it and change the graphic comment and press OK 5) Click around the symbol - the selection box doesn't go away. 6) Click where you would expect a symbol to be if the diagram view was at the top left of the diagram and that symbol will appear. 7) To make it even clearer press F3 to have the diagram redrawn - it will be as if the diagram was not scrolled in the first place.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** SA has scrolled the diagram as intended but then no longer thinks the diagram has scrolled after a symbol definition has been edited. When the user next attempts to interact with the diagram there are unexpected effects - in the first case triggering the rename of the symbol.
Problem conclusion
Problem corrected.
Temporary fix
Comments
APAR Information
APAR number
PI18266
Reported component name
TLOGIC SYS ARCH
Reported component ID
5724V68SA
Reported release
B30
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-05-19
Closed date
2014-06-06
Last modified date
2014-06-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC SYS ARCH
Fixed component ID
5724V68SA
Applicable component levels
RB30 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS6RBX","label":"Rational System Architect"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.3","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
06 June 2014