Fixes are available
APAR status
Closed as program error.
Error description
Title : When trying to use text reporting, the textreport type is flagged as containing a compiler error Description : Attempts to generate code from egl code with Rationa Business Developer cause a compilation error. Error : 'IWN.VAL.9994.i 1/1 Generating part be.testHandler with build descriptor TestReportJavaBuildOptions from file \TestReport\EGLSource\TestReport.eglbld. IWN.VAL.9992.e 0/0 The part testHandler cannot be generated because the part TextReport contains validation or syntax errors. IWN.VAL.9997.e 7/0 Generation failed for be.testHandler.' Workaround: No workaround known
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** The TextReport part was referring to NativeType, which is no longer supported. When the report.eglar was regenerated, it flagged this reference as an error. When the user tried to reference TextReport in their code, the TextReport part error was detected and the usage of it was then flagged saying that the reference part contained validation or syntax errors.
Problem conclusion
The resolution was to change the processor to allow EGL system parts to be able to reference NativeType and then regenerate report.eglar. A fixtest is available.
Temporary fix
Comments
APAR Information
APAR number
PI14322
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
901
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-03-24
Closed date
2015-03-23
Last modified date
2015-03-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R901 PSN
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
14 October 2021