Fixes are available
APAR status
Closed as program error.
Error description
When calling a web services from Windows phone 8 application via adapter procedure call, while in progress if the user send application on background and back again the application will crash. The following exception will appear: System.NullReferenceException: Object reference not set to an instance of an object. at IBM.Worklight.WLNativeXHRSender.responseCallback(IAsyncResult asyncResult) at System.Net.Browser.ClientHttpWebRequest.<>c__DisplayClass1d. <InvokeGetResponseCallback>b__1b(Object state2)} A first chance exception of type 'System.NullReferenceException' occurred in worklight-windowsphone8.DLL Worklight Versions Affected: 7.x Initial Impact: Medium
Local fix
No local fix provided
Problem summary
**************************************************************** * USERS AFFECTED: * * All Application users using MobileFirst platform version 70 * * and 710 * **************************************************************** * PROBLEM DESCRIPTION: * * Windows phone 8 application crashes when returning back to * * the application just after it is sent to background while * * the response from adapter call to server is incomplete. * **************************************************************** * RECOMMENDATION: * * NONE * ****************************************************************
Problem conclusion
Code is fixed to avoid this crashing.
Temporary fix
Comments
APAR Information
APAR number
PI46152
Reported component name
WL/MFPF ENTERPR
Reported component ID
5725I4300
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-08-04
Closed date
2015-11-25
Last modified date
2015-11-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WL/MFPF ENTERPR
Fixed component ID
5725I4300
Applicable component levels
R700 PSY
UP
R710 PSY
UP