Troubleshooting
Problem
Attempts to archive in IBM Rational DOORS results in the message "Could Not Write All of Files" and the item is not archived.
Cause
DOORS uses the Dynazip tool to create and restore archives. This mechanism does not support UNC paths.
Diagnosing The Problem
Items to check if the database server is configured to use a mapped drive letter:
- Verify that there is enough free disk space available on your target drive
- Verify you have write access to the target drive
Note: Be aware that network drives may have restrictions
Resolving The Problem
Do not use a Universal Naming Convention (UNC) path when defining the location of the SERVERDATA used by DOORS database server.
[{"Product":{"code":"SSKR2T","label":"IBM Engineering Requirements Management DOORS"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"General Information","Platform":[{"code":"PF033","label":"Windows"}],"Version":"9.2;9.1.0.2;9.1;9.0;8.3;8.2","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]