Error description
When using a copybook with a zoned decimal and he ISO-8859-1 encoding any change is made to a message action and saved, closed and re-opened in test factory then a '+' (or '-') is added after the zoned decimal in the next field and all subsequent bytes are pushed forward by one. This does not happen when using the (default) CP037 encoding.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of Rational Integration Tester working with zoned * * decimals in Copybooks. * **************************************************************** * PROBLEM DESCRIPTION: * * Zoned decimals in Copybooks generally include the sign part * * of the number as an overpunch in the last digit of the * * serialized form. This overpunch was previously included for * * EBCDIC-based character sets, but not for ASCII-based * * characters, which meant that ASCII-based messages were being * * corrupted. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
A fix for this issue was provided in version 8.7.0.2 of Rational Integration Tester. Overpunch support has been added for the ASCII-based character sets.
Temporary fix
Comments
APAR Information
APAR number
PI40260
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-05-01
Closed date
2015-07-10
Last modified date
2015-07-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSY
UP