A fix is available
APAR status
Closed as program error.
Error description
Customer's got the following ABEND: Dump Title: SLIP DUMP ID=KV CPU Model 2817 Version 00 Serial no. 169AA6 Address 002 Date: 04/28/2015 Time: 12:42:34.287442 Local . . . CPU STATUS: PSW=07042000 80000000 00000000 2DD6ABAE (Running in PRIMARY, key 0, AMODE 31, DAT ON) Disabled for PER Chain processing terminated - ASID(X'0084') 00000000 has already been processed ASID(X'0084') 2DD6ABAE. AREA(Subpool252Key00)+2BAE IN EXTENDED PRIVATE ASID(X'0084') 2DD6ABAE. KO2EC01F+2BAE IN EXTENDED PRIVATE ASCB133 at FB1700, JOB(OMND5), for the home ASID ASXB133 at 8FDB60 and TCB133BT at 8A9B00 for the home ASID HOME ASID: 0085 PRIMARY ASID: 0084 SECONDARY ASID: 0085 PSW points to: ... *** COPYRIG | HT (C) 1977,1988 | - 2010 IBM CORP | ORATION *** .... | O2EC01 V510510 | 12/05/14 05:52.. | PI25519 DB2COM | MVS510 . COPYRI | GHT IBM CORP. 20 | 14 JUPDT | . . . The root of the problem is "Interval Processing" in Object Analysis that updates control blocks
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - OA - Object Analysis * **************************************************************** * PROBLEM DESCRIPTION: ABEND 0C9-009 in KO2EC01F * * at X'2BAE' offset * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** PROBLEM SUMMARY: Incorrect counter for cycle was set. PROBLEM CONCLUSION: Change logic to provide correct counter for cycle. KEYWORDS: ABEND 0C9-009 KO2EC01F
Problem conclusion
Change logic to provide correct counter for cycle.
Temporary fix
Comments
APAR Information
APAR number
PI40257
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-05-04
Closed date
2015-07-22
Last modified date
2017-01-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI29601 UI29602 UI29603 UI29604
Modules/Macros
KO2EOJAB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R510 PSY UI29601
UP15/07/24 P F507
R511 PSY UI29602
UP15/07/24 P F507
R520 PSY UI29603
UP15/07/24 P F507
R530 PSY UI29604
UP15/07/24 P F507
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]