A fix is available
APAR status
Closed as program error.
Error description
If you add a JAR file to the "lib" folder of a Java adapter, the classpath to the JAR file is set to a full path instead of a relative path. This leads to an invalid path reference when the user moves the project and calls the adapter from another workstation.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * MobileFirst Developers that utilize Java adapters in 7.0.0 * **************************************************************** * PROBLEM DESCRIPTION: * * If you add a JAR file to the "lib" folder of a Java adapter, * * the * * classpath to the JAR file is set to a full path instead of a * * relative path. This leads to an invalid path reference when * * the * * user moves the project and calls the adapter from another * * workstation. * **************************************************************** * RECOMMENDATION: * * - * ****************************************************************
Problem conclusion
The class path entry will be changed from a full path to a workspace-relative path.
Temporary fix
Comments
APAR Information
APAR number
PI39927
Reported component name
WL/MFPF CONSUME
Reported component ID
5725I4301
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-04-27
Closed date
2015-05-06
Last modified date
2015-05-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WL/MFPF CONSUME
Fixed component ID
5725I4301
Applicable component levels
R700 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"700","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
17 October 2021