A fix is available
APAR status
Closed as program error.
Error description
SCCNSAM(MYEPILOG) macro generates incorrect code when CCN_DSASZ = 0
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of XL C/C++ using myepilog sample in * * SCCNSAM * **************************************************************** * PROBLEM DESCRIPTION: The DSASZ in the sample code myepilog * * macro is zero and there is no * * savearea, however in the epilogue code * * generated code to load back caller's * * save area. Correct the problem with a * * new sample. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Apply provided service.
Temporary fix
Comments
APAR Information
APAR number
PI39482
Reported component name
C/C++ FOR MVS
Reported component ID
56551210A
Reported release
790
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-04-20
Closed date
2015-04-20
Last modified date
2016-05-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI26898
Modules/Macros
CCNGEPIL
Fix information
Fixed component name
C/C++ FOR MVS
Fixed component ID
56551210A
Applicable component levels
R790 PSY UI26898
UP15/05/12 P F505
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"790","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSQKCWV","label":"IBM C\/C++ for MVS\/ESA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"790","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]