Error description
DUMP TITLE: OMEGAMON II FOR DB2: COMPID=5655OPE00, JOB=O2CI33 LMOD=KO2CDB22#L, CSECT=O2CNAS , OFFSET=000BCE OB0910: Program Check - Recovery Successful-CNAS+0BCE received on ZHATACT screen when zooming on thread. The navigation path to error is as follows: H HISTORICAL ........... Near-Term History information B THREAD HISTORY Screen ZHAFL: Enter date, time and planname Screen ZHARP: B-BY AUTHID Screen ZHAGAU: Zoom PF11 on thread Screen ZHATACT: ABEND0C9 ABEND0C9 rc09 in LMOD KO2CDB22#L CSECT KO2CNASB+BCA (PK47721) on a CVB instruction, 4FE06148. Reg6 offset x'148' = x'000002970958765C', a value whose result won't fit in 32 bits. Since the value is outside the range 2,147,483,647 to -2,147,483,648 a fixed-point-divide exception is recognized. This failure is very similar to PK51796 where the program check occurs because of bad data, instead of good data outside the allowable range for binary conversion.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - Classic Interface * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C9 IN the load module KO2CDB22, * * CSECT O2CNAS, OFFSET BCE * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: A numeric value was not processed correctly. PROBLEM CONCLUSION: Changed logic to prevent a program check.
Problem conclusion
Changed logic to prevent a program check. KEYWORDS : ABEND0C9 KO2CDB22,
Temporary fix
Comments
APAR Information
APAR number
PK61992
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-02-29
Closed date
2008-05-20
Last modified date
2017-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK36606
Modules/Macros
KO2APC5A KO2APC5S KO2APC52 KO2APC6A KO2APC6S KO2APC62 KO2APC7A KO2APC7S KO2APC72 KO2APC8A KO2APC8S KO2APC82 KO2CNADB KO2CNASB KO2ONASB KO2OTHAB KO2OTHDB KO2OTHFB KO2OTHLB KO2OTH3B KO2OTH8B KO2OZM2B KO2WGETB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R410 PSY UK36606
UP08/05/21 P F805
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]