A fix is available
APAR status
Closed as program error.
Error description
Running a batch accounting TRACE with exception should produce a report. The sysin statement: ACCOUNTING TRACE LAYOUT(LONG) EXCEPTION results in The output "no data to return" is incorrect.
Local fix
sysin as ACCOUNTING REPORT LAYOUT(SHORT) EXCEPTION EXEC should produce results
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - PE Server * * - Batch Reporting * **************************************************************** * PROBLEM DESCRIPTION: In Batch processing the ACCOUNTING * * TRACE with EXCEPTION option did not * * return any trace records. The threshold * * dataset was defined to check for * * elapsed time class 1 violations. But * * even though there must have been * * threads that violated the threshold for * * the elapsed time class 1 field * * (ADRECETT) the trace output was empty. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: Enhancements were added to also honor ROLLUP threads during exception processing of field ADRECETT (elapsed time class 1) in batch exception processing. PROBLEM CONCLUSION: Enhancements now enable exception processing to honor ROLLUP threads for field ADRECETT (elapsed time class 1)
Problem conclusion
Enhancements now enable exception processing to honor ROLLUP threads for field ADRECETT (elapsed time class 1). KEYWORDS : ADRECETT ROLLUP ACCOUNTING TRACE EXCEPTION
Temporary fix
Comments
APAR Information
APAR number
PK61667
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-02-25
Closed date
2008-03-04
Last modified date
2008-04-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK34275 UK34276
Modules/Macros
DGOFECAL DGOFEDPM
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]