IBM Support

PK56868: KD261SO2 RECORD-555 ERROR IN ICAT PANEL

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • KD261SO2 RECORD-555 ERROR IN ICAT PANEL
    
    The problem appeared when the customers were doing Omegamon
    DB2PE configuration via ICAT process.
    
    KCICTALR ***************************************
    KCICTALR FATAL ERROR DETECTED, RC = 20
    KCICTALR FUNCTION: FTINCL KD261SJ5
    KCICTALR )SEL error
    KCICTALR )SEL has no matching )ENDSEL, KD261SO2 record-555
    KCICTALR ***************************************
    KD261CB2 ***************************************
    KD261CB2 FATAL ERROR DETECTED, RC = 24
    KD261CB2 FUNCTION: UNKNOWN
    KD261CB2 ***************************************
    KCICSTMC ***************************************
    KCICSTMC FATAL ERROR DETECTED, RC = 24
    KCICSTMC FUNCTION: UNKNOWN
    KCICSTMC ***************************************
    
    The customers have been told to apply ISPF PTFs, e.g. OA20688,
    OA18587, and to make sure tthat  the TKANCUS dataset is defined
    properly (fixformat, record length 80).
    
    KD261SO2 will be updated to not use the continuation character
    "?".  We will not use the continuation character "?".
    

Local fix

  • Update KD261SO2 to not use the continuation character "?"
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   ICAT                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: In one file-tailoring skeleton the      *
    *                      continuation character ? is used. That  *
    *                      causes problems in customer             *
    *                      environments.                           *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF.                              *
    ****************************************************************
    PROBLEM SUMMARY:
    In a file-tailoring skeleton the continuation character ? is use
    used. That causes problems in some customer environments.
    
    PROBLEM CONCLUSION:
    The same logic is coded without using the continuation
    character.
    If you encountered this problem you have to regenerate the
    runtime members after you have installed this PTF. To do that:
    1. Navigate to the main menu of 'OMEGAMON XE for DB2 Performance
    Expert on z/OS'.
    2. Select option 3 'Create runtime members'.
    3. Select option 2 'DB2 subsystem selection/install DB2 related
    members'
    4. Select the DB2 subsystems that you want to monitor. Press
    ENTER, then press F3.
    5. A job is generated. Submit this job.
    

Problem conclusion

  • The same logic is coded without using the continuation
    character.
    If you encountered this problem you have to regenerate the
    runtime members after you have installed this PTF. To do that:
    1. Navigate to the main menu of 'OMEGAMON XE for DB2 Performance
    Expert on z/OS'.
    2. Select option 3 'Create runtime members'.
    3. Select option 2 'DB2 subsystem selection/install DB2 related
    members'
    4. Select the DB2 subsystems that you want to monitor. Press
    ENTER, then press F3.
    5. A job is generated. Submit this job.
    
    KEYWORDS :
    DB2 SUBSYSTEM DESCRIPTION BATCH MODE INSTALL Z/OS SYSTEM ID
    NUMBER CONTINUATION CHARACTER ?
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK56868

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-11-20

  • Closed date

    2007-11-29

  • Last modified date

    2007-12-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK31719 UK31720

Modules/Macros

  •    KD2CTBEX KD260OS  KD260SO2 KD261PN  KD261SO2
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R310 PSY UK31719

       UP07/11/30 P F711

  • R410 PSY UK31720

       UP07/11/30 P F711

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
05 December 2007