A fix is available
APAR status
Closed as program error.
Error description
This problem is due to the failure of IMS Connect to provide a framing event after a transaction times out on a persistent socket. As a result of this missing event, IMS Connect Extensions fails to delineate two transactions and may route the second one incorrectly. This APAR will provide toleration for this problem until IMS Connect APAR PK53653 is closed. This APAR will also fix the following: Command destined for an IMSPLEX is routed incorrectly if the IMSPLEX Tmember name matches a CEX Datastore group name. The command request is sent to one of the datastores in the datastore group instead of the IMSPLEX.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Users of IMS Connect Extensions V1.2. * **************************************************************** * PROBLEM DESCRIPTION: Excluded transactions are routed * * incorrectly. * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR provides: Toleration for an issue in IMS Connect (PMR86205) that causes problems in routing. Prevents messages from the IMS component of DB2 Control Center from being routed (PMR40852).
Problem conclusion
The problem identified by PMR86205 is due to the failure of IMS Connect to provide a framing event after a transaction times out on a persistent socket. As a result of this missing event, IMS Connect Extensions fails to delineate two transactions and potentially routes the second transaction incorrectly. The problem identified by PMR40852 is due to commands destined for an IMSPLEX being routed incorrectly if the IMSPLEX TMEMBER name matches an IMS Connect Extensions Datastore group name. The command request is sent to one of the datastores in the datastore group instead of the IMSPLEX. After applying this fix, Restart your IMS Connect Extensions system.
Temporary fix
Comments
APAR Information
APAR number
PK53787
Reported component name
IMS CONNECT EXT
Reported component ID
5655K4800
Reported release
120
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2007-09-28
Closed date
2007-11-06
Last modified date
2007-12-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK30967
Modules/Macros
CEXEXRTR
Fix information
Fixed component name
IMS CONNECT EXT
Fixed component ID
5655K4800
Applicable component levels
R120 PSY UK30967
UP07/11/10 P F711
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Connect Extensions"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"120"}]
Document Information
Modified date: