Error description
Dump Title: OMEGAMON II FOR DB2: COMPID=5655OPE00, JOB=CANSO2 , LMOD=KO2CDB22#L, CSECT=O2CNTP , OFFSET=000ABA CPU Model 2094 Version 00 Serial no. 055410 Address 00 Date: 08/21/2007 Time: 10:44:42.129480 Local Original dump dataset: SP.DUMP.D070821.T104416.SYS5.CANSO2.S00002 Information at time of entry to SVCDUMP: HASID 0113 PASID 0113 SASID 0113 PSW 070D1000 A35C6E40 CML ASCB address 00000000 Trace Table Control Header address 7F192000 . . . PIDS/5655OPE00 RIDS/KO2CDB22#L RIDS/O2CNTP ADRS/000ABA LVLS/410 Symptom Symptom data Explanation --------------- ------------- ----------- PIDS/5655OPE00 5655OPE00 Component identifier RIDS/KO2CDB22#L KO2CDB22#L Routine identifier RIDS/O2CNTP O2CNTP Routine identifier ADRS/000ABA 000ABA Storage address LVLS/410 410 Program product release level . . . CPU STATUS: PSW=070D1000 A35C6E40 (Running in PRIMARY, key 0, AMODE 31, DAT ON) DISABLED FOR PER ASID(X'0113') 235C6E40. KO2OCNTB+011968 IN EXTENDED PRIVATE ASID(X'0113') 235C6E40. AREA(Subpool252Key00)+011E40 IN EXTENDED PRIVATE ASCB275 at F4BB00, JOB(CANSO2), for the home ASID ASXB275 at 9FDCF8 for the home ASID. No block is dispatched HOME ASID: 0113 PRIMARY ASID: 0113 SECONDARY ASID: 0113 Omegamon doesn't correctly process performance trace records in case when they includes self defining sections with Non-zero offset and zero length Additional Symptoms: OB0910: Program Check - Recovery Successful-CNTP+0AA2 occurs in V310 of OMPE. . OB0910: Program Check - Recovery Successful-CNTP+0ABA occurs in V410 of OMPE.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - Classic Interface * **************************************************************** * PROBLEM DESCRIPTION: Incorrect process performance trace * * records for 22 IFCID * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: INCORRECT PROCESS PERFORMANCE TRACE RECORDS FROM SELF DEFINING SECTIONS WITH NON-ZERO OFFSET AND 0 LENGTH PROBLEM CONCLUSION: CHANGED CODE FOR CORRECT PROCESSING PERFORMANCE TRACE RECORDS FOR 22 IFCID
Problem conclusion
CHANGED CODE FOR CORRECT PROCESSING PERFORMANCE TRACE RECORDS FOR 22 IFCID KEYWORDS : INCORROUT PROCESS PERFORMANCE TRACE RECORDS 22 IFCID
Temporary fix
Comments
APAR Information
APAR number
PK52876
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2007-09-14
Closed date
2007-11-15
Last modified date
2017-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
OA22810 PK54547 UK31274
Modules/Macros
KO2ACAPA KO2ACAPS KO2ACAP2 KO2DCS2B KO2DMSCA KO2DMSCS KO2DMSC2 KO2DTHDA KO2DTHDS KO2DTHD2 KO2DXS2A KO2DXS2S KO2DXS22 KO2HDTIB KO2HPRCB KO2HSQIB KO2HVINB KO2TSB1B KO2TSB2B KO2TSB3B KO2TSB4B
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R410 PSY UK31274
UP07/11/17 P F711
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]