A fix is available
APAR status
Closed as program error.
Error description
Abend SD23 ( D23 abendD23 SD23 ) after SVC x'23' WTOR is issued by module IRTXRI00 @ PK39154 at offset x'92E'. R15=05010004 means the WTOR text length is 0. This happens when AUTOWTOR=YES during an extended restart.
Local fix
No work around.
Problem summary
**************************************************************** * USERS AFFECTED: All IMS Program Restart Facility users. * **************************************************************** * PROBLEM DESCRIPTION: PRF abends SD23 during an extended * * restart when the AUTOWTOR=YES option * * has been specified. * **************************************************************** * RECOMMENDATION: * **************************************************************** Program Restart should not ABENDD23 if option AUTOWTOR=YES is selected as a job processing option. A change to an option parsing routine made in PK44755 which prevents some user- specified options from being recognized has also been corrected.
Problem conclusion
Program Restart has been corrected to prevent the SD23 abend from occurring and to properly recognize all user-specified product options.
Temporary fix
Comments
APAR Information
APAR number
PK47944
Reported component name
IMS PGM RESTART
Reported component ID
5655E1400
Reported release
210
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2007-06-27
Closed date
2007-07-18
Last modified date
2007-08-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK27214
Modules/Macros
IRTAOPT0 IRTXRI05 IRTXRI06 IRTXRI07 IRTXRI08 IRTXRI09 IRTXRI10
Fix information
Fixed component name
IMS PGM RESTART
Fixed component ID
5655E1400
Applicable component levels
R210 PSY UK27214
UP07/07/20 P F707 Ø
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSAVHR","label":"IMS Program Restart Facility for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]