A fix is available
APAR status
Closed as program error.
Error description
O21421 HISTORICAL COLLECTOR - WORKLOAD DANALYZE HAD LOOPED MORE THAN TEN TIMES System experiences high CPU and historical collection eventually shuts down
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - OMEGAMON Server * **************************************************************** * PROBLEM DESCRIPTION: O2142I Historical Collector - * * Workload DANALYZE has looped more * * than 10 times. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: Intermittent High CPU when processing IFCID 3 & 239 accounting records. PROBLEM CONCLUSION: Correct IFCID 239 process, improvements to internal diagnostic path and replace the User abends 1200, 5002, 5003, 4920 and 4921 with SDUMPx services.
Problem conclusion
Correct IFCID 239 process, improvements to internal diagnostic path and replace the User abends 1200, 5002, 5003, 4920 and 4921 with SDUMPx services. KEYWORDS : HIGH CPU HISTORICAL DANALYZE O2142I WORKLOAD XM#ENTRY ABEND0C1 ABEND0C4 RECOVERY KO2ACONB $TCA ZERO
Temporary fix
Comments
APAR Information
APAR number
PK47224
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
310
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-06-15
Closed date
2007-11-22
Last modified date
2007-12-14
APAR is sysrouted FROM one or more of the following:
OA21460
APAR is sysrouted TO one or more of the following:
UK31532 UK31533
Modules/Macros
KO2DATA KO2DTHDA KO2DTHDS KO2DTHD2 KO2HSVPB KO2ORCVB KO2OSNEC KO2OSNEF KO2OSNPB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
14 December 2007