A fix is available
APAR status
Closed as program error.
Error description
High Performance Sysgen gets an abend Abend S337-04 when processing command 'IOHXEDIT' selecting the EDIT function. Similar problems for VERIFY and INSTALL in panel IOH@PRIM. This happens only if the data set specified isn't a PDS. Code will be changed to verify that the data set is a PDS before reading the directory.
Local fix
Specify a PDS as the data set.
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Sysgen V2R2 users. * **************************************************************** * PROBLEM DESCRIPTION: ABEND337 if IOHPDS data set name * * specified on main menu is a * * sequential file. * **************************************************************** * RECOMMENDATION: * **************************************************************** ABEND337 if IOHPDS data set name specified on main menu is a sequential file. Correct error message numbers issued by IOHBRVRS. Terminal security updates and undo list entries are not saved correctly in the IOHPDS. Message IOH4402E possible when installing an update list with an update CTRANS entry.
Problem conclusion
Verify that IOHPDS is a PDS before reading directory Correct 2 error message numbers issued by Batch Reverse utility. Correct error that may cause some Resource Update lists not to be saved.
Temporary fix
Comments
×**** PE07/08/17 PTF IN ERROR. SEE APAR PK51232 FOR DESCRIPTION
APAR Information
APAR number
PK44696
Reported component name
IMS HP SYSGEN T
Reported component ID
5655F4300
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2007-05-07
Closed date
2007-05-30
Last modified date
2007-08-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK25654
Modules/Macros
IOHBRVRS IOHDCB IOHXEMBR IOHXLOG4 IOHXPDS IOHXPDS2 IOHXVIEW IOHZCHK0 IOHZCHK7 IOHZCHK8 IOHZCHK9 IOHZMTX7 IOHZMTX8 IOHZMTX9
Fix information
Fixed component name
IMS HP SYSGEN T
Fixed component ID
5655F4300
Applicable component levels
R220 PSY UK25654
UP07/05/31 P F705
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.