IBM Support

PK38153: TIME DELAYS BETWEEN THE GENERATION AND LOGGING OF AN IMS MESSAGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • There seems to be a signicant delay between the timestamps
    of a message when it is generated and when it appears in the
    SM log.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: SM USERS WHO HAVE VENDOR / USER TYPE-1       *
    *                 AOI EXIT DFSAOUE0 INSTALLED ALONG WITH       *
    *                 SM'S TYPE-2 AOI EXIT DFSAOE00                *
    ****************************************************************
    * PROBLEM DESCRIPTION: IMS MTO MESSAGES ARE NOT SENT TO        *
    *                      IMS SYSPLEX MANAGER LOG IN TIME DUE     *
    *                      TO A LOGIC ERROR IN SM'S TYPE-1         *
    *                      AOI EXIT DFSAOUE0. THE RESULT IS        *
    *                      MTO MESSAGES APPEAR IN SM LOG WITH      *
    *                      A DELAYED TIMESTAMP .                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    SM'S AOI EXIT DFSAOUE0 WAS CHANGED TO SEND MTO MESSAGES
    AS SOON AS THEY ARE GENERATED BY IMS.
    

Problem conclusion

  • FIXED
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK38153

  • Reported component name

    IMS SYSPLEX MGR

  • Reported component ID

    5655P0100

  • Reported release

    120

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2007-01-25

  • Closed date

    2007-02-05

  • Last modified date

    2007-03-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK21872

Modules/Macros

  • GJEIAOEA GJEIAOEX GJEIAOE8 GJEIAOE9
    

Fix information

  • Fixed component name

    IMS SYSPLEX MGR

  • Fixed component ID

    5655P0100

Applicable component levels

  • R120 PSY UK21872

       UP07/02/06 P F702

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8AA","label":"IMS Sysplex Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 March 2007