A fix is available
APAR status
Closed as program error.
Error description
CBL V6.1 Compile ends in RC=16 IGYCB7104-U INTERNAL ERROR WHILE COMPILING FUNCTION SSCHRTRO. FAILED ASSERTION ON ../Z/CODEGEN/FPTREEEVALUATOR.CPP:1136. COMPILATION TERMINATED.
Local fix
Compile using OPT(0)
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.2 compiling * * programs at ARCH(11) that move floating * * point data (including using FUNCTION * * NUMCONV) to PACKED-DECIMAL or USAGE * * DISPLAY data items. * **************************************************************** * PROBLEM DESCRIPTION: Compiler ABORT with message * * MSGIGYCB7104-U INTERNAL ERROR WHILE * * COMPILING FUNCTION 'XXXX'.FAILED * * ASSERTION ON * * ../Z/CODEGEN/FPTREEEVALUATOR.CPP:1136. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** The compiler was creating a floating-point-to-packed-decimal conversion without correctly truncating the packed-decimal value to the appropriate number of digits.
Problem conclusion
The compiler was fixed to property truncate the packed-decimal value.
Temporary fix
Comments
APAR Information
APAR number
PI90577
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-11-22
Closed date
2017-11-27
Last modified date
2018-06-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2 IGYCOPI IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYSIDEK IGYZQDRV
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UP
A
R621 PSY UP
A
R622 PSY UI56122
UP18/06/01 P F805
R62H PSY UP
A
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: